HPGM-14BP (380 V)

MONOBLOC R32 DC INVERTER · Air-to-Water Heat Pump

HPGM-14BP (380 V)

Cooling: 13.5 kW
Heating: 14,0 kW

The HPGM-14BP (380V) is a heavy-duty, high-output air-to-water monobloc heat pump with a nominal capacity of 14.0 kW, specifically engineered to run on a stable three-phase 380V electrical supply. We recommend this model for spacious modern homes, multi-level townhouses, and light commercial spaces ranging from 120 to 150 m². If your property has three-phase power available and demands robust, consistent heating and domestic hot water (DHW)—but falls just short of requiring a massive 16 kW climate engine—this model is the perfect, highly efficient choice. Because it is a monobloc, all hydraulic components are housed outdoors, saving valuable indoor utility space.



Official warranty
Delivery across Ukraine

Year-Round Comfort

This three-phase system is designed for reliable year-round performance, certified for stable heating in outdoor temperatures down to -25°C, and highly effective cooling in summer up to +43°C (via underfloor/wall cooling loops or active fan coils). SENSEI's advanced DC inverter control ensures the system maintains target water temperatures with an accuracy of 0.5°C, preventing draft sensations and ensuring stable indoor comfort.

Technical Advantages & Features

  • Top-Tier Seasonal Efficiency (A+++ Class): The full DC inverter system extracts up to 75% of its thermal energy directly from the ambient air, significantly lowering your seasonal utility bills.

  • Balanced Three-Phase (380V) Operation: Spreading the electrical load evenly across three phases prevents voltage drops and phase imbalances on local grids, ensuring stable operation during the coldest winter days.

  • All-in-One Outdoor Concept: The outdoor unit integrates all essential components (high-efficiency plate heat exchanger, DC water pump, expansion vessel, flow switch, and safety valves), delivering a pre-assembled, ready-to-use water heating circuit.

  • Premium Twin-Rotary DC Compressor: Features a highly reliable inverter compressor with advanced acoustic blankets for whisper-quiet outdoor performance.

  • Eco-Friendly R32 Refrigerant: Optimized for low-GWP R32 refrigerant, which improves heat transfer efficiency by 10% and reduces the overall refrigerant charge volume.

  • Wired Touchscreen Controller: Includes an intuitive wired controller to manage complex weather-dependent heating curves, DHW sanitization (Anti-Legionella) cycles, and active scheduling.

Installation & Operation Insights

  • From our engineering teams' experience: For the three-phase 14 kW model, we highly recommend installing a buffer tank (typically 80 to 100 liters) to guarantee smooth defrost cycles and prevent compressor short-cycling.

  • Since the monobloc is filled with water and sits entirely outdoors, safeguarding against power grid outages in freezing weather is critical. We strongly advise filling the system with a certified propylene glycol-based thermal fluid or installing specialized mechanical freeze-protection valves (such as Ice-Stop valves).

  • Installation is straightforward and clean—no on-site refrigerant piping, brazing, or flaring is required. The installer only connects insulated water lines from the outdoor unit to the building's manifold.

Comparison: HPGM-14BP (380V) vs. HPGM-16BP (380V)

While both models share the same heavy-duty three-phase outdoor chassis, choosing between the HPGM-14BP (380V) and the flagship HPGM-16BP (380V) depends on your property's specific size and thermal load.

Feature / Metric HPGM-14BP (380V) HPGM-16BP (380V)
Nominal Thermal Capacity 14.0 kW 16.0 kW
Recommended Heating Area 120 – 150 m² 150 – 200 m²
Compressor Power Draw Lower peak current consumption Higher peak current consumption
Sub-Zero Output Reserve Ideal balance for mid-large homes Maximum thermal output reserve in deep frosts
DHW Recovery Time Rapid recovery Maximum speed for very large-volume tanks

Key Takeaways from the Comparison:

  1. Preventing Short-Cycling (Tac-ing): If your home is under 150 m², selecting the HPGM-14BP (380V) is the technically correct decision. Running the 16 kW model in a space that is too small forces the compressor to constantly turn on and off (short-cycle), which reduces seasonal efficiency (COP) and shortens the compressor's operational lifespan.

  2. Electrical Load Optimization: The 14 kW model draws less starting and running current per phase than the 16 kW flagship. If your local grid has strict power limitations, the 14 kW version provides a safer electrical margin while still delivering massive heating capacity.

  3. Efficiency at Partial Loads: For homes in the 120–150 m² range, the HPGM-14BP operates closer to its optimal partial-load efficiency during mild winter days, ensuring a higher overall seasonal performance coefficient than an under-loaded 16 kW unit.

Best Suited For:

  • Owners of medium-to-large residences (120–150 m²) with three-phase power who want a highly efficient, space-saving heating and cooling system.

  • Properties with extensive underfloor heating networks where a balanced, stable grid load is essential.

Might Not Be Suited For:

  • If your home's heated area exceeds 150–160 m² or has high heat losses, the HPGM-16BP (380V) is required to handle the load without relying on backup electrical heaters.

  • If your property is under 100 m², both models are oversized; you should look at the single-phase HPGM-10BP or HPGM-8BP instead.

PACKAGE CONTENTS

  • Indoor unit
  • Outdoor unit
  • Remote control
  • Installation manual
  • Warranty card

Got an error? Check its meaning here.

DC inverter compressor

Pressure ratio up to 13, high performance in low ambient temperatures.

DC motor

Brushless DC motor: high efficiency, low noise level.

Refrigerant cooling

Keeps the main PCB operating within the proper temperature range for greater reliability.

High-efficiency BPHE heat exchanger

Excellent air-duct design that withstands high temperatures and high pressure.

EXV valve

Precise refrigerant flow control and regulation, 0-480 pulses

Inverter water pump

High-efficiency inverter water pump with a high water head of up to 9 m.

KEY SPECIFICATIONS

Cooling (kW)
13.5
Heating (kW)
14,0
Refrigerant Type
R32
Power Supply
380~415V/3Ph/50Hz
Capacity (kW)
3
Type
R32
Expansion Device
EXV
Refrigerant Loading
2,6 kg
Expansion Tank (volume, L)
5
Number of Phases
3
Permissible Operating Pressure (MPa)
0.3
Inverter Water Pump
Yes
Water-Side Resistance (kPa)
45
Evaporator (water volume, L)
1,45
Maximum Permissible Pressure (MPa)
4,4
refrigerant_topup
2,6 kg

PERFORMANCE

Energy Efficiency Class
A+++
Current Draw (A)
11+13,6 A
Coolant temperature (water) (Cooling)
5~25 °C
Coolant temperature (water) (Heating)
25~62 °C
SCOP/SEER Energy Efficiency
4,94/6,37 kW
Power Consumption (kW)
6,6+3,0 kW
Hot Water Temperature
25~60 °C

SOUND AND CONVENIENCE

Outdoor Unit Noise Level (dB)
69

INSTALLATION AND PIPING

Operating Temperatures (card)
-25~50 °C
Connecting Pipe Diameter (outlet)
DN25
Connecting Pipe Diameter (inlet)
DN25

OUTDOOR UNIT DIMENSIONS AND WEIGHT

Net/Gross Weight (kg)
182,9/202,9 kg
Packaged Dimensions (W×H×D, mm)
1364x518x1690 mm
Outdoor Unit Dimensions (W×D×H)
1302x465x1517 mm

OTHER SERIES