MONOBLOC R32 DC INVERTER · Air-to-Water Heat Pump
HPGM-14BP (380 V)
The HPGM-14BP (380V) is a heavy-duty, high-output air-to-water monobloc heat pump with a nominal capacity of 14.0 kW, specifically engineered to run on a stable three-phase 380V electrical supply. We recommend this model for spacious modern homes, multi-level townhouses, and light commercial spaces ranging from 120 to 150 m². If your property has three-phase power available and demands robust, consistent heating and domestic hot water (DHW)—but falls just short of requiring a massive 16 kW climate engine—this model is the perfect, highly efficient choice. Because it is a monobloc, all hydraulic components are housed outdoors, saving valuable indoor utility space.
MODELS
Year-Round Comfort
This three-phase system is designed for reliable year-round performance, certified for stable heating in outdoor temperatures down to -25°C, and highly effective cooling in summer up to +43°C (via underfloor/wall cooling loops or active fan coils). SENSEI's advanced DC inverter control ensures the system maintains target water temperatures with an accuracy of 0.5°C, preventing draft sensations and ensuring stable indoor comfort.
Technical Advantages & Features
-
Top-Tier Seasonal Efficiency (A+++ Class): The full DC inverter system extracts up to 75% of its thermal energy directly from the ambient air, significantly lowering your seasonal utility bills.
-
Balanced Three-Phase (380V) Operation: Spreading the electrical load evenly across three phases prevents voltage drops and phase imbalances on local grids, ensuring stable operation during the coldest winter days.
-
All-in-One Outdoor Concept: The outdoor unit integrates all essential components (high-efficiency plate heat exchanger, DC water pump, expansion vessel, flow switch, and safety valves), delivering a pre-assembled, ready-to-use water heating circuit.
-
Premium Twin-Rotary DC Compressor: Features a highly reliable inverter compressor with advanced acoustic blankets for whisper-quiet outdoor performance.
-
Eco-Friendly R32 Refrigerant: Optimized for low-GWP R32 refrigerant, which improves heat transfer efficiency by 10% and reduces the overall refrigerant charge volume.
-
Wired Touchscreen Controller: Includes an intuitive wired controller to manage complex weather-dependent heating curves, DHW sanitization (Anti-Legionella) cycles, and active scheduling.
Installation & Operation Insights
-
From our engineering teams' experience: For the three-phase 14 kW model, we highly recommend installing a buffer tank (typically 80 to 100 liters) to guarantee smooth defrost cycles and prevent compressor short-cycling.
-
Since the monobloc is filled with water and sits entirely outdoors, safeguarding against power grid outages in freezing weather is critical. We strongly advise filling the system with a certified propylene glycol-based thermal fluid or installing specialized mechanical freeze-protection valves (such as Ice-Stop valves).
-
Installation is straightforward and clean—no on-site refrigerant piping, brazing, or flaring is required. The installer only connects insulated water lines from the outdoor unit to the building's manifold.
Comparison: HPGM-14BP (380V) vs. HPGM-16BP (380V)
While both models share the same heavy-duty three-phase outdoor chassis, choosing between the HPGM-14BP (380V) and the flagship HPGM-16BP (380V) depends on your property's specific size and thermal load.
| Feature / Metric | HPGM-14BP (380V) | HPGM-16BP (380V) |
| Nominal Thermal Capacity | 14.0 kW | 16.0 kW |
| Recommended Heating Area | 120 – 150 m² | 150 – 200 m² |
| Compressor Power Draw | Lower peak current consumption | Higher peak current consumption |
| Sub-Zero Output Reserve | Ideal balance for mid-large homes | Maximum thermal output reserve in deep frosts |
| DHW Recovery Time | Rapid recovery | Maximum speed for very large-volume tanks |
Key Takeaways from the Comparison:
-
Preventing Short-Cycling (Tac-ing): If your home is under 150 m², selecting the HPGM-14BP (380V) is the technically correct decision. Running the 16 kW model in a space that is too small forces the compressor to constantly turn on and off (short-cycle), which reduces seasonal efficiency (COP) and shortens the compressor's operational lifespan.
-
Electrical Load Optimization: The 14 kW model draws less starting and running current per phase than the 16 kW flagship. If your local grid has strict power limitations, the 14 kW version provides a safer electrical margin while still delivering massive heating capacity.
-
Efficiency at Partial Loads: For homes in the 120–150 m² range, the HPGM-14BP operates closer to its optimal partial-load efficiency during mild winter days, ensuring a higher overall seasonal performance coefficient than an under-loaded 16 kW unit.
Best Suited For:
-
Owners of medium-to-large residences (120–150 m²) with three-phase power who want a highly efficient, space-saving heating and cooling system.
-
Properties with extensive underfloor heating networks where a balanced, stable grid load is essential.
Might Not Be Suited For:
-
If your home's heated area exceeds 150–160 m² or has high heat losses, the HPGM-16BP (380V) is required to handle the load without relying on backup electrical heaters.
-
If your property is under 100 m², both models are oversized; you should look at the single-phase HPGM-10BP or HPGM-8BP instead.
PACKAGE CONTENTS
- Indoor unit
- Outdoor unit
- Remote control
- Installation manual
- Warranty card
Got an error? Check its meaning here.
DC inverter compressor
Pressure ratio up to 13, high performance in low ambient temperatures.
DC motor
Brushless DC motor: high efficiency, low noise level.
Refrigerant cooling
Keeps the main PCB operating within the proper temperature range for greater reliability.
High-efficiency BPHE heat exchanger
Excellent air-duct design that withstands high temperatures and high pressure.
EXV valve
Precise refrigerant flow control and regulation, 0-480 pulses
Inverter water pump
High-efficiency inverter water pump with a high water head of up to 9 m.
KEY SPECIFICATIONS
- Cooling (kW)
- 13.5
- Heating (kW)
- 14,0
- Refrigerant Type
- R32
- Power Supply
- 380~415V/3Ph/50Hz
- Capacity (kW)
- 3
- Type
- R32
- Expansion Device
- EXV
- Refrigerant Loading
- 2,6 kg
- Expansion Tank (volume, L)
- 5
- Number of Phases
- 3
- Permissible Operating Pressure (MPa)
- 0.3
- Inverter Water Pump
- Yes
- Water-Side Resistance (kPa)
- 45
- Evaporator (water volume, L)
- 1,45
- Maximum Permissible Pressure (MPa)
- 4,4
- refrigerant_topup
- 2,6 kg
PERFORMANCE
- Energy Efficiency Class
- A+++
- Current Draw (A)
- 11+13,6 A
- Coolant temperature (water) (Cooling)
- 5~25 °C
- Coolant temperature (water) (Heating)
- 25~62 °C
- SCOP/SEER Energy Efficiency
- 4,94/6,37 kW
- Power Consumption (kW)
- 6,6+3,0 kW
- Hot Water Temperature
- 25~60 °C
SOUND AND CONVENIENCE
- Outdoor Unit Noise Level (dB)
- 69
INSTALLATION AND PIPING
- Operating Temperatures (card)
- -25~50 °C
- Connecting Pipe Diameter (outlet)
- DN25
- Connecting Pipe Diameter (inlet)
- DN25
OUTDOOR UNIT DIMENSIONS AND WEIGHT
- Net/Gross Weight (kg)
- 182,9/202,9 kg
- Packaged Dimensions (W×H×D, mm)
- 1364x518x1690 mm
- Outdoor Unit Dimensions (W×D×H)
- 1302x465x1517 mm
OTHER SERIES