HPGM-14BP

MONOBLOC R32 DC INVERTER · Air-to-Water Heat Pump

HPGM-14BP

Cooling: 13.5 kW
Heating: 14,0 kW

The HPGM-14BP is a near-commercial grade, fully integrated air-to-water monobloc heat pump with a robust nominal heating capacity of 14.0 kW (typically configured for a stable three-phase 380V electrical supply). We recommend this high-output model for spacious private homes, multi-level residences, and light commercial properties ranging from 140 to 160 m². It is the ultimate engineering choice for larger buildings that require substantial thermal output across extensive underfloor heating loops, low-temperature radiators, or fan coils, but lack interior utility space. Because the entire hydraulic circuit is self-contained inside the outdoor monobloc chassis, no indoor space is required for a hydro-module.



Official warranty
Delivery across Ukraine

Year-Round Comfort

This heavy-duty monobloc system is engineered to deliver stable heating in outdoor temperatures down to -25°C, and highly effective cooling in summer up to +43°C (by supplying chilled water to fan coils or underfloor/wall cooling loops). Driven by an advanced DC inverter controller, the system maintains the target water temperature within a precise 0.5°C range, eliminating temperature fluctuations and ensuring consistent, draught-free indoor comfort.

Technical Advantages & Features

  • Top-Tier Seasonal Efficiency (A+++ Class): Utilizing full DC inverter technology on the compressor, fan, and water pump, the system extracts up to 75% of its thermal energy from the ambient air, drastically reducing winter heating bills compared to standard electric boilers.

  • All-in-One Concept: The outdoor unit houses all essential hydraulic components, including a high-efficiency plate heat exchanger, a DC water pump, an expansion vessel, a flow switch, and safety valves. It outputs a ready-to-use water heating circuit directly.

  • Premium DC Inverter Compressor: Features a highly reliable twin-rotary inverter compressor with advanced acoustic and thermal insulation, keeping vibration and outdoor operating noise to an absolute minimum.

  • Eco-Friendly R32 Refrigerant: Optimized to run on low-GWP R32 refrigerant, which increases thermodynamic heat transfer efficiency by 10% and requires a smaller refrigerant charge volume.

  • Wired Controller Included: Comes with an intuitive wired touchscreen controller to program customized weather-dependent heating curves, vacation modes, weekly schedules, and domestic hot water (DHW) priorities.

Installation & Operation Insights

  • From our engineering teams' experience: Since the monobloc is filled with water and sits entirely outdoors, we pay meticulous attention to frost protection in regions with potential winter power outages. We strongly recommend filling the heating system with a certified propylene glycol-based thermal fluid or installing specialized mechanical freeze-protection valves (such as Ice-Stop valves).

  • For the HPGM-14BP, installing a buffer tank (typically 80 to 100 liters) is highly recommended to ensure smooth defrost cycles without dropping the indoor system's temperature.

  • Installation is exceptionally clean and rapid: because the refrigerant loop is hermetically sealed at the factory, there is zero need for copper line brazing or flaring on site. The installer only needs to connect insulated water pipes from the monobloc directly to the building's heating manifold.

Comparison with the Previous HPGM-12BP Model

While both units belong to SENSEI's compact monobloc range, the HPGM-14BP offers key capacity and performance upgrades over the HPGM-12BP (12.0 kW):

  • Increased Thermal Output: Delivering 14.0 kW compared to the 12.0 kW of the 12-model, this system easily supports larger residential spaces (up to 160 m² vs 140 m²) and provides faster hot water recovery times in domestic hot water (DHW) tanks.

  • Superior Heating Capacity in Cold Weather: The 14.0 kW model retains a larger absolute heating output at sub-zero temperatures, reducing the need for auxiliary electric backup heaters during peak winter frosts.

  • Higher Flow Rate Compatibility: The integrated circulation pump and heat exchanger in the HPGM-14BP are designed to handle larger water flow volumes, making it more suitable for properties with more extensive underfloor heating loops and more complex hydraulic distributors.

Best Suited For:

  • Owners of large townhouses, smart homes, and residences (140–160 m²) who want to transition to green energy without sacrificing indoor utility space.

  • Projects looking for a fast, straightforward installation that minimizes on-site labor and eliminates the need for complex refrigerant piping.

Might Not Be Suited For:

  • If your home's total heated area is under 120 m², the 14.0 kW capacity may be oversized, leading to inefficient compressor cycling; in this scenario, the HPGM-12BP or HPGM-10BP is the more balanced, economical choice.

  • If you live in an area prone to long, unmanaged winter blackouts and do not wish to use glycol or freeze-protection valves in your heating system, a split-type system remains a safer choice because its water-bearing parts are protected indoors.

PACKAGE CONTENTS

  • Indoor unit
  • Outdoor unit
  • Remote control
  • Installation manual
  • Warranty card

Got an error? Check its meaning here.

DC inverter compressor

Pressure ratio up to 13, high performance in low ambient temperatures.

DC motor

Brushless DC motor: high efficiency, low noise level.

Refrigerant cooling

Keeps the main PCB operating within the proper temperature range for greater reliability.

High-efficiency BPHE heat exchanger

Excellent air-duct design that withstands high temperatures and high pressure.

EXV valve

Precise refrigerant flow control and regulation, 0-480 pulses

Inverter water pump

High-efficiency inverter water pump with a high water head of up to 9 m.

KEY SPECIFICATIONS

Cooling (kW)
13.5
Heating (kW)
14,0
Refrigerant Type
R32
Power Supply
220~240V/1Ph/50Hz
Capacity (kW)
3
Type
R32
Expansion Device
EXV
Refrigerant Loading
2,6 kg
Expansion Tank (volume, L)
5
Number of Phases
1
Permissible Operating Pressure (MPa)
0.3
Inverter Water Pump
Yes
Water-Side Resistance (kPa)
45
Evaporator (water volume, L)
1,45
Maximum Permissible Pressure (MPa)
4,4

PERFORMANCE

Energy Efficiency Class
A+++
Current Draw (A)
30+13,6 A
Coolant temperature (water) (Cooling)
5~25 °C
Coolant temperature (water) (Heating)
25~62 °C
SCOP/SEER Energy Efficiency
4,94/6,37 kW
Power Consumption (kW)
6,6+3,0 kW
Hot Water Temperature
25~60 °C

SOUND AND CONVENIENCE

Outdoor Unit Noise Level (dB)
69

INSTALLATION AND PIPING

Operating Temperatures (card)
-25~50 °C
Connecting Pipe Diameter (outlet)
DN25
Connecting Pipe Diameter (inlet)
DN25

OUTDOOR UNIT DIMENSIONS AND WEIGHT

Net/Gross Weight (kg)
167,7/184,4 kg
Packaged Dimensions (W×H×D, mm)
1364x518x1690 mm
Outdoor Unit Dimensions (W×D×H)
1302x465x1517 mm

OTHER SERIES

View All