SPLIT R32 DC INVERTER · Air-to-Water Heat Pump
HPGS-V12HW/ HPGS-V12HN
The HPGS-V12HW / HPGS-V12HN is a highly efficient split-type air-to-water heat pump with a nominal thermal capacity of 12.0 kW (powered by a single-phase 220V supply). The system consists of the outdoor unit (HPGS-V12HN) and the indoor hydro-module (HPGS-V12HW). We recommend this balanced "12-kW" setup for mid-sized homes, townhouses, and modernized cottages ranging from 100 to 120 m². It serves as an excellent all-in-one primary system for heating, active summer cooling, and domestic hot water (DHW) generation.
MODELS
Year-Round Comfort
This low-temperature split system is certified to deliver stable heating at extreme winter temperatures down to -28°C, and highly effective cooling in summer up to +43°C. Running on reversible technology, it channels chilled water through floor cooling loops or fan coils during peak summer heat. Guided by an advanced DC inverter controller, it manages water temperature delivery with an accuracy of 0.5°C, ensuring optimal comfort without thermal overshoot.
Technical Advantages & Features
-
Top-Tier Seasonal Efficiency (A+++ Class): The system operates at a highly economical performance level, extracting up to 75% of its total thermal output from the ambient air, which significantly minimizes winter heating bills.
-
Safe Split Construction: All water-bearing hydraulic elements are contained entirely inside the indoor hydro-module (HPGS-V12HW). This completely eliminates any risk of outdoor pipes freezing or cracking during unexpected winter power grid outages.
-
Premium DC Inverter Compressor: Houses a high-performance inverter compressor featuring enhanced acoustic blankets and dual-stage rotary operation for low-vibration, whisper-quiet performance.
-
Ozone-Safe R32 Refrigerant: Optimized for high-pressure R32 refrigerant, improving the system’s thermodynamic heat transfer efficiency by 10% and reducing the overall environmental footprint.
-
Color Touchscreen Controller: Features an integrated, user-friendly wired touch controller to program complex weather-dependent heating curves, DHW sanitization cycles, and priority settings.
Installation & Operation Insights
-
From our engineering teams' experience: For the HPGS-V12HW / HPGS-V12HN, a properly sized buffer tank (typically 50 to 80 liters) is essential to ensure a clean defrost cycle and prevent short-cycling.
-
We mount the outdoor unit on heavy-duty floor brackets with specialized anti-vibration rubber dampers to keep mechanical hum away from the structure. Since the connection between the indoor hydro-module and outdoor unit relies exclusively on copper refrigerant line sets (1/4" liquid and 1/2" gas), the installer does not need to run water pipes outdoors, which streamlines the installation process.
Best Suited For:
-
Owners of mid-sized private homes and cottages (100–120 m²) who want to transition away from traditional gas, solid fuel, or inefficient electric boilers to a single, high-efficiency green energy system.
-
Regions with harsh winter climates, where the freeze-safe split design protects the hydraulic system from damage during power outages.
Might Not Be Suited For:
-
If the total heated area of your property is well under 80 m², the 12 kW capacity is redundant; in this scenario, the more compact HPGS-V8HW / HPGS-V8HN is the more balanced, economical choice to prevent unnecessary system cycling.
PACKAGE CONTENTS
- Indoor unit
- Outdoor unit
- Remote control
- Installation manual
- Warranty card
Got an error? Check its meaning here.
High pressure-ratio compressor
High pressure-ratio compressor — up to 13 — with better performance at low ambient temperatures. Renowned GMCC brand. DC rotary inverter compressor. Refrigerant: R32.
DC fan motor
Brushless DC fan motor. Higher efficiency, low noise level
Larger heat exchanger
A larger heat exchanger to match the required heat-exchange area at low ambient temperatures. Flat-type fins improve defrosting efficiency.
Integrated PCB
The integrated PCB for the single-phase unit reduces the risk of damage to each component.
Plate heat exchanger
Efficient heat transfer for both heating and cooling. Compact footprint. Withstands high temperatures and high pressure.
Inverter water pump
High-efficiency inverter water pump. Brand: Wilo Para series. Water head is 9 m for the 8 kW, 12 kW, and 16 kW hydronic modules. CE and VDE compliant, 50/60 Hz.
Expansion tank
When water heats up, it expands and its pressure rises. Without room for thermal expansion, serious problems can occur in the water system, including failure or rupture. The expansion tank maintains stable pressure in the water system. Pre-charge pressure: 0.15 MPa. Volume: 2 L.
KEY SPECIFICATIONS
- Compressor Type
- Rotary DC inverter
- Power Supply
- 220~240/1/50 V/Ph/Hz
- Capacity (kW)
- 12
- Poles
- 6
- Speed (rps)
- 12~120
- Oil
- POE/1000mL
- Motor Type
- Brushless DC motor
- Number of Fans
- 1
- Heat Exchanger Rows
- 2,5
- Compressor model
- EKTF310D43UMT
- Charge Volume (kg)
- 3,1
- Tube Pitch × Row Pitch (mm)
- 25x21,7
- Heat Exchanger Tube Type and Diameter
- Ф9.52 grooved copper pipe
- Fin Spacing (mm)
- 1,6
- Heat Exchanger Fin Type
- Hydrophilic aluminum
- Heat Exchanger Dimensions
- 1003x750x43,3 + 580x750x21,65
- Number of Turns
- 5
- Pipe Diameter (OD, mm)
- Ф9.52
- Expansion Device
- EXV
- Compressor Manufacturer
- GMCC
- Safety Valve (kPa)
- 600
- Expansion Tank (volume, L)
- 2
- Pump Head (m)
- 9
- Number of Phases
- 1
- Max. water pressure (kPa)
- 800 kPa
- Nominal pressure (kPa)
- 150 kPa
- Rated power consumption (kW)
- 3kW
- Rated current (A)
- 13,6A
- refrigerant_topup
- (Total pipeline length is -5)m*30 g/m
PERFORMANCE
- Air Flow (m³/h)
- 4000 m3/godz
- EER Energy Efficiency
- 2,7 kW/kW
- COP Energy Efficiency
- 3,4
- Maximum Current Draw (A)
- 22
- Energy Efficiency Class (water 35°C)
- А++
- Energy Efficiency Class (water 55°C)
- А++
- Max. Power Consumption (kW)
- 5
- Max. power consumption, indoor (kW)
- 3,6 kW
- Max. current, indoor (A)
- 17 A
- SCOP Energy Efficiency
- 4,14 kW/kW
- Power Consumption (kW)
- 2,9
- Hot Water Temperature
- 40~60°C
- Hot water supply, indoor (°C)
- 40~60°C
SOUND AND CONVENIENCE
- Indoor Unit Noise Level (dB)
- 45
- Outdoor Unit Noise Level (dB)
- 68
INSTALLATION AND PIPING
- Maximum Line Length (m)
- 50 m
- Operating Temperatures (Heating)
- -28~43°C
- Operating Temperatures (Cooling)
- -5~46°C
- Liquid Pipe Diameter (mm)
- Ф9.52
- Gas Pipe Diameter (mm)
- Ф15.88
- Height Difference (above, m)
- 20
- Height Difference (below, m)
- 20
- Connecting Pipe Diameter (outlet)
- DN32
- Connecting Pipe Diameter (inlet)
- DN32
- Cooling water temp, indoor (°C)
- 5~25 °C
- Cooling water temp, outdoor (°C)
- 5~25°C
- Heating water temp, outdoor (°C)
- 25~60°C
- Heating water temp, indoor (°C)
- 25~60°C
INDOOR UNIT DIMENSIONS AND WEIGHT
- Indoor Unit Weight (kg)
- 48/56 kg
- Packing W×H×D, indoor (mm)
- 620*1105*425 mm
- Indoor Unit Dimensions (W×D×H)
- 490*910*340 mm
OUTDOOR UNIT DIMENSIONS AND WEIGHT
- Outdoor Unit Weight (kg)
- 67,5/70,5 kg
- Packaged Dimensions (W×H×D, mm)
- 1075x875x495 mm
- Outdoor Unit Dimensions (W×D×H)
- 1032x810x445 mm
OTHER SERIES
View All