HPGS-V12HW + HPGS-V12HN
-
HPGS-V16HW + HPGS-V16HN ( / )
-
HPGS-V14HW + HPGS-V16HN ( / )
-
HPGS-V10HW + HPGS-V12HN ( / )
-
HPGS-V8HW + HPGS-V8HN ( / )
-
HPGS-V5HW + HPGS-V8HN ( / )
- Description
- Main advantages
- Technical parameters
Description
Split type heat pump system
- Includes hydronic module, no extra insulation of hot water pipes.
- Produce domestic hot water all year.
- Heating in winter and cooling in summer.
- Wide range of solutions: floor heating, radiators and fan coils.
- Create great comfort at home even at low outdoor temperatures.
- Environmental friendly: using R32 refrigerant.
Wide operation temperature range
- Provide comfortable home even with extreme outdoor temperature.
Full capacity in low ambient temperature
- Due to the high pressure ratio compressor, the heat pump has 85% of rated capacity even in -15℃.
Hot water temperature range
- In cooling mode, the water outlet temperature range is 5~25℃.
- In heating mode, the water outlet temperature range is 25~60℃.
- In hot water mode, the water outlet temperature range is 40~60℃.
Capture energy from ambient air
- Heat pump captures heat energy from the ambient air and transfers it to heat the water.
- Up to 75% of the heat energy required is taken from the ambient air.
Touch screen wired controller
- Standard with touch screen wired controller, more functions can be realized and it is easier to operate.
- Wired controller can be took away from hydronic module, and installed in the room, to detect room temperature.
- An additional cover is provided.
Wired controller functions
- Window design, easy to operate & view
- Mode control, temperature setting, heating mode,
- cooling mode, DHW mode, combination mode
- Weekly timer function
- Electric heater
- Forced defrosting
- Sterilization
- Anti-freezing protection
- WIFI control (optional)
Main advantages
Technical parameters
| Power supply | 220~240/1/50 V/Ph/Hz |
| Nominal heating*1 | ||
| Performance | 12 kW | |
| Power consumption | 2,9 kW | |
| СОР | 4,14 kW/kW | |
| Nominal cooling*2 | ||
| Performance | 10 kW | |
| Power consumption | 3,7 kW | |
| EER | 2,7 kW/kW | |
| Heating*3 | ||
| Power consumption | 3,53 kW | |
| Performance | 12 kW | |
| COP | 3,4 kW/kW | |
| Cooling*4 | ||
| Performance | 10 kW | |
| Power consumption | 2,08 kW | |
| EER | 4,8 kW/kW | |
| Seasonal energy efficiency | ||
| Outlet water at 35°C | А++ | |
| Outlet water at 55°C | А++ | |
| Мах. Power consumption Outdoor unit | 5 kW |
| Мах. Power consumption Indoor unit | 3,6 kW |
| Мах. Current consumption Outdoor unit | 22 A |
| Мах. Current consumption Indoor unit | 17 A |
| Noise level Outdoor unit | 68 dB(A) |
| Noise level Indoor unit | 45 dB(A) |
| Technical parameters | ||
| Dimensions (W x H x D) Outdoor unit | 1032x810x445 mm | |
| Dimensions (W x H x D) Indoor unit | 490*910*340 mm | |
| Packing (W x H x D) Outdoor unit | 1075x875x495 mm | |
| Packing (W x H x D) Indoor unit | 620*1105*425 mm | |
| Net/gross weight Outdoor unit | 67,5/70,5 kg | |
| Net/gross weight Indoor unit | 48/56 kg | |
| Compressor | ||
| Brand | GMCC | |
| Type | Rotary DC inverter | |
| Model | EKTF310D43UMT | |
| Poles | 6 | |
| Speed | 12~120 rps | |
| Oil | POE/1000mL | |
| Outdoor unit fan | ||
| Brand | Yongan | |
| ENGINE TYPE | Brushless DC motor | |
| Model | DRN-310-90-8 | |
| Number of fans | 1 | |
| Airflow | 4000 m3/godz | |
| Heat exchanger | ||
| Number of rows | 2,5 | |
| Pipe spacing (a) x row spacing (b) | 25x21,7 mm | |
| Txp and pipe diameter | Ф9.52 grooved copper pipe | |
| Plate spacing | 1,6 mm | |
| Plate type | Hydrophilic aluminum | |
| Length x height x width | 1003x750x43,3 + 580x750x21,65 mm | |
| Number of coils | 5 | |
| Liquid | ||
| Type | Soldering | |
| Diameter (OD) | Ф9.52 mm | |
| Gas | ||
| Type | Soldering | |
| Diameter (ОD) | Ф15.88 mm | |
| Мах. Pipe length | 50 m |
| Мах. Height difference | ||
| Outdoor unit (top) | 20 m | |
| Outdoor unit (bottom) | 20 m | |
| Refrigerant | ||
| Type | R32 | |
| Quantity | 3,1 kg | |
| Throttle type | EXV | |
| Additional filling | (Total pipeline length is -5)m*30 g/m | |
| Outdoor temperature range | ||
| Cooling | -5~46°C | |
| Heating | -28~43°C | |
| Water temperature range | ||
| Cooling Indoor unit | 5~25 °C | |
| Cooling Outdoor unit | 5~25°C | |
| Heating Outdoor unit | 25~60°C | |
| Heating Indoor unit | 25~60°C | |
| Hot water supply Outdoor unit | 40~60°C | |
| Hot water supply Indoor unit | 40~60°C | |
| Diameter of connecting pipe | ||
| Exit | DN32 mm | |
| Inlet | DN32 mm | |
| Safety valve | 600 kPa |
| Expansion tank | ||
| Volume | 2 L | |
| Мах. Water pressure | 800 kPa | |
| Nominal pressure | 150 kPa | |
| Heat exchanger | ||
| Type | Plate | |
| Volume | 1,22 L | |
| Water pump | ||
| Brand | wilo | |
| Model | Para 25/9 | |
| Lifting height | 9 m | |
| Circulation of refrigerant | ||
| Diameter of the supply pipeline (liquid) | Ф9.52 mm | |
| Diameter of the return (gas) pipeline | Ф15.88 mm | |
| Reserve electric heater (tubular heater) | ||
| Power supply | 230V/1Ph/50Hz | |
| Performance | 3kW | |
| Number of phases | 1 | |
| Мах. Power consumption | 3kW | |
| Мах. Current consumption | 13,6A | |